Prospects of application of iron-containing carbon-paste electrode in electrochemical analysis
dc.contributor.author | Shlyapov, Rustam | |
dc.contributor.author | Uali, Aitolkyn | |
dc.contributor.author | Amerkhanova, Shamshiya | |
dc.date.accessioned | 2020-11-04T11:13:56Z | |
dc.date.available | 2020-11-04T11:13:56Z | |
dc.date.issued | 2020-08 | |
dc.description.abstract | The literature analysis devoted to the number of electrochemical sensors developed for metal ions is growing. This is due to the modification of already known classical electronic systems, or the use of new materials in the production of solid-phase, membrane, gas electrodes. One of these systems is a carbon-paste electrode, which belongs to the group of heterogeneous carbon electrodes. The ability to select an electrode-active substance for a specific research task is the main advantage of these electrochemical sensors. For example, an active electrode material was synthesized a polymer metal complex of lead(II) to determine lead ions in a solution [1]. The application of expensive reagents such as ethylene glycol dimethacrylate is the one of the disadvantages of them. Therefore, the purpose of the work was the identifying possibility of application an environmentally friendly natural material for modifying the carbon-paste electrode and determining iron ions in aqueous solutions. The active electrode material (iron-containing carbonized wool) was characterised by modern physical and chemical methods (scanning electron microscope (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), thermal analysis (TG-DTA)). The analytical characteristics of the iron(III)-containing electrode were also determined in the direct potentiometry mode: 1.00·10-4 mol/l was taken, 9.20·10-5 mol/l was found (n = 5, P=0.95, Sx=4.74·10-6), relative error of the determination 8% and during potentiometric titration with a solution of ethylenediamintetraacetic acid in the presence of sulfuric acid (0.001 mol/l): ΔE= 4.4 mV, 1.0 · 10-3 mol/l was taken, 0.95 · 10-3 mol/l was found, Sr=1.92·10-5, n=5, P=0.95, the relative error of the determination 0.2 %. Therefore the amount of iron (II) in aqueous solutions can be determined potentiometrically with a modified carbon-paste electrode. | en_US |
dc.identifier.uri | http://nur.nu.edu.kz/handle/123456789/5068 | |
dc.language.iso | en | en_US |
dc.publisher | The 8th International Conference on Nanomaterials and Advanced Energy Storage Systems; Nazarbayev University; National Laboratory Astana; Institute of Batteries | en_US |
dc.rights | Attribution-NonCommercial-ShareAlike 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.subject | electrochemical analysis | en_US |
dc.subject | metal ions | en_US |
dc.subject | thermal analysis | en_US |
dc.subject | Research Subject Categories::TECHNOLOGY | en_US |
dc.subject | carbon electrodes | en_US |
dc.title | Prospects of application of iron-containing carbon-paste electrode in electrochemical analysis | en_US |
dc.type | Abstract | en_US |
workflow.import.source | science |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Abstract book INESS 2020.page57.pdf
- Size:
- 332.63 KB
- Format:
- Adobe Portable Document Format
- Description:
- Abstract
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 6.28 KB
- Format:
- Item-specific license agreed upon to submission
- Description: